NODE:SHARED ▸ AIR-SCRUBBER
ALORAIR Air Scrubber
3-Stage — MERV-10 Pre-Filter + HEPA + Activated Carbon
ALORAIR 3-stage air scrubber — MERV-10 pre-filter catches coarse particulate, HEPA traps fine dust and aerosols, activated carbon scrubs VOCs and breaks down residual ozone. Stackable, heavy-duty, industrial-grade. Runs continuous during shop operations and shifts to full-speed for O₃ clearance after sterilization cycles. Negative air capable when ducted — critical for containment during hazmat or high-particulate jobs.
7 specs7 capabilities4 refsOPERATIONAL
SPECIFICATIONS
Filtration3-stage: MERV-10 pre-filter → HEPA (particulate) → activated carbon (VOC/O₃)
TypeStackable negative air machine — industrial/commercial grade
CoverageFull-shop air exchange — Lab, Forge, and Resurrection zones
Primary TargetsResin VOCs, laser cutting fumes, powder coat overspray, residual O₃
Negative AirCapable — creates negative pressure for containment when ducted
Run ModeContinuous during operations; full-speed for O₃ clearance cycles
O₃ SafetyCarbon stage breaks O₃ → O₂ — active clearance for ozone sterilization cycles
CAPABILITIES
3-stage filtration — MERV-10 → HEPA → activated carbonParticulate capture — laser/CNC dust, powder coat oversprayActivated carbon VOC scrubbing — resin fumes, solvents, paintsO₃ destruction — carbon catalytic breakdown of residual ozone after sterilizationNegative air capable — ducted mode for containmentStackable — multiple units can be staged for larger volumeFull-shop coverage during all active operations
TRAINING_&_REFERENCE
📝
Filter Replacement Schedulenote
MERV-10 pre-filter: check weekly, replace when loaded. HEPA: check monthly. Carbon stage: replace based on VOC breakthrough or every 6 months. Log replacements for OSHA/air quality documentation.
📝
O₃ Clearance Protocolnote
After ozone sterilization cycle, run scrubber at full speed for clearance period. Verify with O₃ monitor before re-entry. Carbon stage is the primary O₃ destruct pathway.
📝
Negative Air Setupnote
Duct exhaust to exterior for negative-pressure containment. Stack additional units for larger volume. Seal room envelope for proper pressure differential.
📝
Resin Safetynote
Scrubber MUST be running during any resin printing or post-processing. Nitrile gloves + safety glasses still required. Refer to resin-specific SDS.
NOTES
Shop-wide infrastructure — supports Lab, Forge, and Resurrection simultaneously. The carbon stage is the bridge between the O₃ sterilization system and occupied-space safety. Stackable design means a second unit scales coverage linearly. Red.